Three-Phase 400V 4KW HS1N-4R0-T4B-110
The HS1 Series AC Servo Drive enables full closed-loop servo control for AC induction motors and permanent magnet synchronous motors, integrating speed control, position control, and torque control into one unit.
With rich interfaces and easy operation, the HS1 Series AC Servo Drive supports standard applications without the need for tuning, greatly facilitating selection, design, and debugging work for mechanical design engineers. Its seamless compatibility with CNC and PLC systems from major domestic and international brands offers flexible integration, helping to highlight your machine’s competitive edge.
As a high-power servo drive unit, the HS1 Series excels in spindle control of CNC machine tools, forging equipment, printing machinery, hydraulic servo systems, wire drawing equipment, and other high-power servo drive applications—offering outstanding cost performance.

Products Description
Hs1 Series
Naming Rules

Spindle Drive Selection Table
| Model | HS1N-4R0-T4B-110 |
| Input Power |
3PH 380V 50/60HZ
Voltage Range 304-456V
Voltage Imbalance Less Than 3%
|
|
Power Capacity (KVA)
|
6 |
|
Input Current (A)
|
10.7 |
|
Output Current (A)
|
9.0 |
|
Compatible Motor (KW)
|
4 |
|
Brake Unit
|
Built-in
|
|
Compatible Resistance (Ω/KW)
|
75/0.8
|
|
Number of Brake Resistors
|
1 |
|
Encoder Type
|
Incremental
|
Compatible Motor

Rich Interface Functions
Mechatrolink-II, EtherCAT high-speed Ethernet bus interface
3 analog input channels, 1 analog output interface
2 relay input interfaces, 1 encoder output interface
1 high-speed pulse input interface
1 set of multifunction differential pulse input interface
Standard RS232 communication interface
07/ 7-channel digital input / 2-channel digital output interface, 2 relay output ports
Excellent Control Performance
Stable ultra-low-speed operation with high torque output
Excellent dynamic response performance
Minimal drive current during no-load operation, maximizing energy-saving performance
Higher precision in position and torque control
Enhanced overload capacity through optimized current vector algorithms and hardware configuration
Comprehensive and Powerful Control Functions
- Speed control
- Torque control
- Position (angle) control
- Coiling tension control
-
Master-slave drive and electronic gear functions
- Fixed-length cutting control
- Single-axis positioning
- Support for external pressure sensors, applicable to hydraulic servo control systems
Spindle Drive Specifications Table
|
Item
|
Description
|
|
|
Output
|
Maximum Output Voltage
|
Three-Phase 380V~440V, Corresponding Input Voltage
|
|
Maximum Output Speed |
12000 RPM
|
|
|
Input
|
Rated Voltage and Frequency
|
Three-Phase 380~440V, 50/60Hz
|
|
Allowed Voltage Fluctuation
|
+10%, -15%
|
|
|
Allowed Frequency Fluctuation
|
±5%
|
|
|
Control
Characteristics
|
Control Method
|
Sine Wave PWM Modulation, Full Closed-Loop Vector Control
|
|
Speed Range
|
1:5000
|
|
|
Speed Control Accuracy
|
±0.02%
|
|
|
Position Control Accuracy
|
±1 Pulse
|
|
|
Frequency Setting Resolution
|
Digital Input 0.01 Hz, Analog Input: Unipolar Max Output Frequency/4096; Bipolar Max Output Frequency/2048
|
|
|
Acceleration/Deceleration Time
|
0~3600s to Max Output Frequency
|
|
|
Braking Method
|
Energy Consumption Braking, Built-in Brake Unit for 93KW and Below
|
|
|
Input/Output
Interface
|
Digital Input
|
Standard Type: 7 Optocoupler-Isolated Inputs; Extended Type: 12 Optocoupler-Isolated Inputs; Input Mode Selectable NPN, PNP
|
|
Digital Output
|
Standard Type: 2 Optocoupler-Isolated Outputs; Extended Type: 4 Optocoupler-Isolated Outputs; Voltage Range: 0~26V,
Max Output Current: 50mA
|
|
|
Analog Input
|
3 Channels: 0~10V, 0~20mA, -10V\~+10V
|
|
|
Analog Output
|
1 Channel, 0/2~10V or 0/4~20mA Optional
|
|
|
Relay Output
|
2 Channels, Two Sets of Normally Open and Normally Closed Contacts; 30VDC 1A
|
|
|
Encoder Input Interface
|
Motor Encoder 1 Channel: Standard 5V Differential, Up to 1MHz, Compatible with 5VOC Up to 100KHz; Rotary Transformer Sine/Cosine Encoder Optional
Spindle Encoder 1 Channel (Optional): 5V Differential, Up to 1MHz, Compatible with 5VOC Up to 100KHz
|
|
|
Pulse Input Interface
|
1 Channel: Direction + Pulse / Quadrature Pulse / CW + CCW
|
|
|
Encoder Output Interface
|
1 Channel: 1:1 or 1:2 Frequency Division Output, Line Driver Type: RS422 Standard
|
|
|
Bus Interface
|
Standard Type: RS485 Bus; Extended Type: CANopen, EtherCAT
|
|
|
Spindle Function
(Only Available on AS650M)
|
Speed Control
|
Range: 0~12000 RPM; Direction: Forward/Reverse; Speed Command: Unipolar/Bipolar Analog, Pulse Frequency, Bus
|
|
Ready Stop Control
|
Accuracy ±1 Pulse; 8 Selectable Terminal Positions
|
|
|
Rigid Tapping
|
Compatible with Various Imported and Domestic Systems, Tapping Error 2%
|
|
|
Other Functions
|
C-Axis Control, Thread Cutting, Electronic Gear, Peck Drilling, Zero Speed Lock
|
|
|
Protection
Function
|
Overload Protection
|
Equipped with Driver and Motor Overload Protection
|
|
Overcurrent Protection
|
Hardware Overcurrent Protection
|
|
|
Undervoltage/Overvoltage Protection
|
Bus Voltage Over 800V Overvoltage Protection, Below 350V Undervoltage Protection
|
|
|
Output Short Circuit Protection
|
Alarm Output on Output Short Circuit
|
|
|
Enable
Environment
|
Usage Environment
|
Indoor Use, No Corrosive Gases
|
|
Temperature
|
-10°C \~ 40°C
|
|
|
Humidity
|
5~95% RH (No Condensation)
|
|
|
Protection Rating
|
Ip20
|
|
|
Overload
|
Current Overload
|
150% Rated Curren t for 1 Minute
|
|
Category
|
Terminal Number
|
Name
|
Analog Input
|
Specification
|
|
|
CN3
|
Analog Input/Output
|
AI1
|
Analog Input 1
|
Analog Input
|
AI1: 0~10V, 0~20MA
|
|
AI2
|
Analog Input 2
|
AI2: -10V\~+10V
|
|||
|
AI3
|
Analog Input 3
|
AI3: 0~10V
|
|||
|
10V
|
+10V Power Supply
|
Analog Input Power Supply
|
Maximum output current: 30mA
|
||
|
GND
|
Analog Common Terminal
|
A11, A12, A13,10Y.AO1 Reference Ground
|
Internally isolated from COM
|
||
|
A01
|
Analog Output 1
|
Provides Analog Output
|
Output Range: 0/210V, 0/420mA
|
||
|
Wiring Terminals
|
PE
|
Shield Ground
|
Used for grounding the shielding
layer of terminal wiring
|
Internally connected to main circuit terminal PE
|
|
|
CN4
|
Multi-function Output
|
Y1
|
Open Collector Output Y1
|
Speed Reached
|
Optically isolated open collector output
Operating voltage range: 0V~26V
Maximum output current: 50mA
|
|
Y2
|
Open Collector Output Y2
|
Ready
|
|||
|
CME
|
Common Terminal
|
Multi-function Output Common Terminal
|
|||
|
Relay 1 |
TA1,TB1,TC1 |
Relay Output |
Fault Output
|
TA1-TB1: Normally closed,
TA1-TC1: Normally open
Contact capacity: 30VDC/1A
|
|
|
Relay 2
|
TA2,TB2,TC2
|
Relay Output
|
Positioning Completion Output
|
TA2-TB2: Normally closed,
TA2-TC2: Normally open
Contact capacity: 30VDC/1A
|
|
|
CN5
|
Multi-function
Input Terminals
|
X1 |
Multi-function Input Terminal 1
|
Speed Run / Forward Rotation
|
NPN/PNP Input Selected By Function Code P3.14;
0V Effective For NPN Input;
24V Effective For PNP Input
|
| X2 | Multi-function Input Terminal 2 |
Reverse Rotation
|
|||
| X3 | Multi-function Input Terminal 3 |
Control Enable
|
|||
| X4 | Multi-function Input Terminal 4 |
Spindle Positioning
|
|||
| X5 | Multi-function Input Terminal 5 |
Rigid Tapping / Pulse Position
|
|||
| X6 | Multi-function Input Terminal 6 |
Programmable Input
|
|||
| X7 | Multi-function Input Terminal 7 |
Programmable Input
|
100K High-Speed Input Supports External Zero Position Switch
|
||
CN7
|
Control Power Supply
|
24V
|
+24V Power Supply
|
Provides +24V External Power Supply
|
Maximum Output Current 200mA
|
|
COM
|
+24V Power Supply Common Terminal
|
Used in combination with other terminals
|
Isolated from GND
|
||
|
Encoder Output
|
OA+\OA-
|
Encoder Signal Output
|
Encoder A Phase Output
|
Optional motor or spindle encoder feedback to the system RS422 standard, selectable 1, 2, or 4 division
|
|
|
0B+\0B-
|
Encoder B Phase Output
|
||||
|
0Z+ \ 0Z-
|
Encoder Z Phase Output
|
||||
|
Pulse Input
|
D+\D-
|
Pulse Command Input
|
CW / Direction Signal / B Phase Input
|
Rs422 Standard, Selectable by Parameter Command Pulse Input Mode
|
|
|
P+\P.
|
CCN/Pulse Signal/A Phase Input
|
||||
|
CN8
|
Incremental Encoder
|
5V\OV
|
Encoder Power and Signal Input
|
Encoder Power Supply
|
|
|
A+ \A-
|
Encoder A Phase Output
|
||||
|
B+\ B-
|
Encoder B Phase Output
|
||||
|
Z+\ Z-
|
Encoder Z Phase Output
|
||||
|
Resolver Encoder
|
EXC +\EXC-
|
Encoder Power and Signal Input
|
Resolver Excitation Signal
|
||
|
SIN+\SIN-
|
Resolver SIN Phase
|
||||
|
COS+\COS.
|
Resolver COS Phase
|
||||
|
Sine-Cosine Encoder
|
5V\ OV
|
Encoder Power and Signal Input
|
Encoder Power Supply
|
||
|
A+\ A-
|
Sine-Cosine A Phase
|
||||
|
B+\ B-
|
Sine-Cosine B Phase
|
||||
|
C+\ C-
|
Sine-Cosine C Phase
|
||||
|
D+\ D-
|
Sine-Cosine D Phase
|
||||
|
R*\ R-
|
Sine-Cosine R Phase
|
||||
|
Absolute Encoder
|
5VOV
|
Encoder Power and Signal Input
|
Encoder Power Supply
|
||
|
DATA+\-
|
Signal Line
|
Spindle Drive Dimensions

Note:For power ratings of 185 kW and above, please consult us.
|
Power (KW)
|
A (mm)
|
B (mm)
|
H (mm)
|
W (mm)
|
D (mm)
|
Installation
aperture
(mm)
|
|
Installation dimensions
|
Overall dimensions
|
|||||
|
4.0-5.5
|
80 | 221.5 | 230 | 105 | 191 |
Φ5
|
| 7.5-11 | 80 | 260 | 270 | 120 | 225 |
Φ5
|
| 15-18.5 | 80 | 275 | 290 | 135 | 235 |
Φ7
|
| 22 | 175 | 378 | 394 | 210 | 220 |
Φ8
|
| 30-45 | 175 | 463 | 477 | 296 | 248 |
Φ8
|
EtherCAT Bus Wiring Diagram

HS1 Control Cable Standard Wiring Diagram

System Configuration

Hot Tags: three-phase 400v 4kw hs1n-4r0-t4b-110, China three-phase 400v 4kw hs1n-4r0-t4b-110 manufacturers, suppliers
Previous
No InformationYou Might Also Like
Send Inquiry